Vacuum furnaces
PVA-LWT uses modern, high-performance vacuum furnaces of
different size and arrangement. Principally two different
types of vacuum heat-treatment furnaces can be distinguished:
- MOV-furnaces:
MOV-furnaces
are fully metal heated furnaces. This means that the heating
insert is made of metals, normally tungsten or molybdenum.
Main characteristic for this furnace type is a very pure
high-vacuum atmosphere, which is nearly free of any carbon-hydrogens.
This enables heat-treatment of very sensitive materials,
such as refractory metals. MOV-furnaces are typically used
for brazing and heat-treatment of tantalum, titanium, niobium
and ceramic materials.
- COV-furnaces:
The heating insert of a COV-furnace, consisting of the insulation
and the heating elements, is made of graphite. These furnaces
are generally equipped with a high-vacuum diffusion pumping
unit.
In contrast to MOV-furnaces the COV-furnaces are more robust
but do not dispose of carbon-hydrogen free vacuum atmosphere.
Therefore COV furnaces are generally used for hardening
processes and brazing of copper alloys and stainless steels.
All furnaces at PVA-LWT are numerically controlled and fulfil
highest requirements with regard to reproducibility of brazing
processes and documentation of process data. As PVA-LWT is
fully embedded in the PVA TePla group, we have short time
access to spare parts and service technicians and thus can
assure a maximum availability of our production furnaces.
Our furnace equipment:
-
MOV 923 T
Capacity: 800x700x1100 mm3 (WxHxL)
Max. operating temperature: 1250°C
Vacuum: max. 1*10-5 mbar
-
MOV 353 T
Capacity: 250x250x620 mm3 (WxHxL)
Max. operating temperature: 1550°C
Vacuum: max. 1*10-6 mbar
-
COV 633 Dif
Capacity: 350x600x600 mm3 (WxHxL)
Max. operating temperature: 1100°C
Vacuum: max. 1*10-5 mbar
-
COV 823 Dif
Capacity: 800x800x1800 mm3 (WxHxL)
Max. operating temperature: 1350°C
Vacuum: max. 1*10-5 mbar
-
MOV 843 CL
Capacity: 700x700x1500 mm3 (WxHxL)
Max. operating temperature: 1350°C
Vacuum: max. 1*10-6 mbar
-
COV 923 Dif
Capacity: 800x1000x1900 mm3 (WxHxL)
Max. operating temperature: 1350 °C
Vacuum: max. 5*10-6 mbar
-
COV 843 Dif
Capacity: 800x800x1800 mm3 (WxHxL)
Max. operating temperature: 1350 °C
Vacuum: max. 1*10-5 mbar
-
COD 264
Capacity: 240x265 mm3 (DxH)
Max. operating temperature: 1700 °C
Vacuum: max. 1*10-2 mbar
Max. Pressure: 100 bar